全部删除看过的历史记录,国产精品福利一区二区,18岁禁止入内,女人张开腿让男人桶爽

    Produkter?Kabelgenomf?ringssystem f?r renrumsteknik

Cable entry systems?for the use in cleanrooms

Cable entry frames & plates for cleanroom technology acc. to ISO 14644

 

A cleanroom is a room that has an extremely low concentration of airborne particles. Airborne particles are all particles and substances that are suspended in the air and for the most part cannot be seen with the naked eye. icotek cable entry systems for cleanrooms are suitable and certified for class 1 in accordance with ISO 14644-1. Find out more ?

icotek cleanroom cable entry systems?at a glance


Filtrera produkter:

Delbar kabelgenomf?ringsram, IP66/UL Type 12/4X*

KT CR-insatsbaserad kabelgenomf?ring med standardh?ltagning f?r industrikontakter. Finns som enkel- eller dubbelradig.

? KEL-ER CR

Delbar kabelgenomf?ringsram, IP54 / UL Type 12

KT CR-insatsbaserad kabelgenomf?ring med standardh?ltagning f?r industrikontakter. Finns som enkel- eller dubbelradig.

? KEL-U CR

Slitsade kabelinsatser f?r renrum, IP66/IP68 / UL Type 12/4X*

Slitsande insatser f?r diametrar 1 till 17 och 16 till 35 mm. Passar KEL CR genomf?ringsramar.

? KT CR

Slitsade multi / specialinsatser f?r renrum, IP54 / UL typ 12

Slitsade insatser f?r diametrar fr?n 1 till 8 mm. L?mplig f?r KEL CR-genomf?ringsramar.

? KT CR multi

Kabelgenomf?ringsplatta med h?g kabelt?thet, upp till IP66 / UL Type 12

Genomf?ringsplatta med h?g kabelt?thet och certifierad skyddsklass upp till IP66/UL typ 12. Finns i varierade storlekar.

? KEL-DPZ CR

Kabelgenomf?ringsplatta, rund, IP66/IP68 / UL Type 12/4X*

Rund genomf?ringsplatta med certifierad skyddsklass IP66/IP68 UL typ 12/4X*. Metriska h?ltagningar M25-M63.

? KEL-DPZ CR rund

Hygienisk kabelgenomf?ringsplatta, rund, IP66/IP68, FDA-kompatibel

Rund hygienisk genomf?ringsplatta med certifierad skyddsklass IP66/IP68. ltagningar M32-M63.

? KEL-DPZ-HD CR rund

Cover panels for thread extensions & cable entry systems, M32 / M50 / M63

The cover panels have an outer diameter of 150 mm and a centre hole of 32.5 mm, 50.5 mm or 63.5 mm to accommodate the thread extensions, cable entry plates & split cable glands.

? AB-M

S?k och filtrera produkter med icotek ProductFinder!

Hitta den perfekta produkten f?r din applikation. Prova det nu!

Such cleanrooms are needed wherever particles present in the ambient air would disrupt production. This is the case, for example, in medical technology, semiconductor production, microsystems technology, pharmaceuticals, aerospace technology or optics. Cleanrooms are also needed in medical research.

Cleanrooms are classified by classes according to ISO 14644-1 as per ISO 1 to 9. The individual cleanroom classes may only contain a certain number of particles of a specified size. The particle concentration is considered per m3 of air. ISO 1 contains the strictest specifications, for ISO 9 the lowest specifications.

In order to be able to meet these strict requirements, materials specially developed / modified by icotek are used in our certified clean room products.

All icotek cable entry systems for the cleanroom tested and certified by the Fraunhofer IPA are suitable and certified for class 1 in accordance with ISO 14644-1!

Cleanroom classes according to ISO 14644-1 and other regulations

Industries and cleanliness criteria

++ mandatory | + recommended, but not mandatory | 0 generally not required but in individual cases recommended (Source: Fraunhofer IPA)

 

Manual disinfection

icotek recommends cleaning products installed in cleanrooms with a mixture of 70% isopropanol and 30% distilled water.

Decontamination with H2O2 vaporisation

Cleanrooms must be cleaned of contamination with microorganisms, particles and pyrogens before each commissioning or after maintenance work. An effective method is cleaning by vaporising hydrogen peroxide (H2O2). The hydrogen peroxide is converted into a gaseous state and the subsequent microcondensation results in optimum decontamination throughout the entire room and on all surfaces.

icotek has subjected its cable entry systems to the H2O2 cleaning process and can recommend its use.  A declaration of conformity is available on request from product management: pm@icotek.com

Not only the particle emissions are relevant but also the outgassing values VOC (Volatile Organic Compounds)/SVOC (Semivolatile Organic Compounds) of the products used in clean rooms. This applies in particular to the semiconductor, optics and aerospace industries.

In the ISO class, the air cleanliness classification works on the basis of the particulate concentration.

In the ISO-ACC class, air cleanliness works on the basis of chemical concentration. The chemical concentration can lead to a chemical contamination, which can have a damaging effect on the product or on the process.

Materials as well as cable entry systems are classified based on their chemical concentration.

ISO-ACCe Class (x) = ISO-Air Cleanliness chemical concentration for equipment = AMC Class Equipment

ISO-ACCm Class (x) = ISO-Air Cleanliness chemical concentration for material = AMC Class Material

The Fraunhofer IPA certified values that were in part no longer measurable in the ultra-trace range and thus excellent to very good values. The material-specific emission rate (= ISO-ACCm class) was determined. The smaller the ISO-ACCm class, the lower the material-specific emission rate.

The test certificates of the Fraunhofer IPA can be requested from icotek: pm@icotek.com